HVAC Refrigeration Tools Tube Piercing Pliers PCP-1 for Refrigerant Recovery

Refrigerant recovery tube piercing pliers are specialized tools used in the HVAC (heating, ventilation, and air conditioning) industry to recover refrigerant from air conditioning and refrigeration systems. These tube piercing pliers are designed to pierce the refrigerant line and allow the technician to safely and efficiently recover the refrigerant from the system. The tube piercing pliers have a sharp, pointed tip that can penetrate the refrigerant line without causing damage to the line or the surrounding components. Refrigerant recovery tube piercing pliers are typically used when the service valves on the refrigerant system are inaccessible or not functioning properly.

Get a Quote

HVAC Refrigeration Tools Tube Piercing Pliers PCP-1 for Refrigerant Recovery

Refrigerant recovery tube piercing pliers are specialized tools used in the HVAC (heating, ventilation, and air conditioning) industry to recover refrigerant from air conditioning and refrigeration systems. These tube piercing pliers are designed to pierce the refrigerant line and allow the technician to safely and efficiently recover the refrigerant from the system. The tube piercing pliers have a sharp, pointed tip that can penetrate the refrigerant line without causing damage to the line or the surrounding components.

Refrigerant recovery tube piercing pliers are typically used when the service valves on the refrigerant system are inaccessible or not functioning properly. They are also useful when working with older systems that do not have service valves. It's important to note that these tube piercing pliers should only be used by trained professionals who are licensed to handle refrigerants. The improper use of refrigerant recovery tools can be dangerous and can result in injury or damage to the environment.

▍Refrigerant Recovery Tube Piercing Pliers PCP-1

Sharp & Durable

• High hardness needle, Forged with alloy tungsten steel.
• Designed to quickly lock on to and pierce refrigerant tube.
• Puncture the refrigeration tube and recover the old refrigerant instantly.
• Manufactured from high-grade heat-treated alloy steel for durability.

Tube Piercing Pliers PCP-1 for Refrigerant Recovery HVAC Refrigeration Tools Tube Piercing Pliers PCP-1

▍Refrigerant Recovery Tube Piercing Pliers PCP-1 Technical Data:

Model HVAC Refrigeration Tools Tube Piercing Pliers PCP-1
Length 220mm
Width 58mm
Suitable Size 4-8mm
Weight 0.43kg

▍Refrigerant Recovery Tube Piercing Pliers Design Features

Refrigerant recovery tube piercing pliers have several design features that make them well-suited for their intended purpose. Some of these design features include:

1. Sharp, pointed tip: The refrigerant recovery tube piercing pliers have a sharp, pointed tip that can penetrate the refrigerant line without causing damage to the line or surrounding components.

2. Locking mechanism: The refrigerant recovery tube piercing pliers often have a locking mechanism that keeps the jaws closed while the technician is piercing the refrigerant line. This helps ensure a secure grip on the line and prevents the pliers from slipping.

3. Ratchet mechanism: Some refrigerant recovery tube piercing pliers may also have a ratchet mechanism that allows the technician to apply even pressure to the refrigerant line as it is being pierced.

4. Comfort grip handles: The refrigerant recovery tube piercing pliers often have comfort grip handles that make them easier to hold and use for extended periods of time.

5. Durable construction: Refrigerant recovery tube piercing pliers are typically made of high-quality materials that are designed to withstand the harsh conditions of an HVAC work environment.

6. Compatibility with various refrigerant lines: The refrigerant recovery tube piercing pliers are designed to pierce various sizes and types of refrigerant lines, making them versatile tools for HVAC technicians.

Overall, the design features of refrigerant recovery tube piercing pliers make them a useful tool for HVAC technicians who need to recover refrigerant from air conditioning and refrigeration systems.

▍Refrigerant Recovery Tube Piercing Pliers Parts

Tube Piercing Pliers Hardened Steel Needle Tube Piercing Pliers Hex Key Adjusting Screw Tube Piercing Pliers 14 SAE Interface Tube Piercing Pliers Hardened Connecting Rod
Tube Piercing Pliers Hardened Steel Needle Tube Piercing Pliers Hex Key Adjusting Screw Tube Piercing Pliers 1/4" SAE Interface Tube Piercing Pliers Hardened Connecting Rod

▍How to Use Refrigerant Recovery Tube Piercing Pliers?

Refrigerant recovery tube piercing pliers are used to recover refrigerant from an air conditioning or refrigeration system. These pliers are designed to pierce the tube of the refrigeration system without damaging it, allowing the refrigerant to be removed. Here are the steps to use refrigerant recovery tube piercing pliers:

(1) Turn off the AC or refrigeration system and allow it to cool down.

(2) Locate the refrigerant line that you want to pierce. This is typically a copper tube that connects the AC unit or refrigerator to the compressor.

(3) Select the correct piercing pin size for the tube you will be piercing. The piercing pin should be slightly smaller than the diameter of the tube.

(4) Insert the piercing pin into the pliers and adjust the tube piercing pliers so that the piercing pin is aligned with the tube.

(5) Squeeze the tube piercing pliers' handles together to pierce the tube. The piercing pin should penetrate the tube without damaging it.

(6) Connect the recovery hose to the piercing pin on the tube piercing pliers.

(7) Turn on the recovery machine and open the valve on the recovery tank.

(8) Allow the refrigerant to be recovered from the system until the pressure gauge on the recovery machine indicates that the system is empty.

(9) Turn off the recovery machine and close the valve on the recovery tank.

(10) Disconnect the recovery hose from the piercing pin on the tube piercing pliers.

(11) Use the tube piercing pliers to remove the piercing pin from the tube.

(12) Dispose of the recovered refrigerant properly according to local regulations.

Note: It's important to follow all safety guidelines and use proper personal protective equipment when working with refrigerants. The use of refrigerant recovery tube piercing pliers should be carried out only by qualified and licensed professionals who are trained in the proper handling of refrigerants and refrigerant recovery equipment. We can also provide other HVAC tools and HVAC equipment for your need, please contact us now.

How to Use Refrigerant Recovery Tube Piercing Pliers How to Use Refrigerant Recovery Tube Piercing Pliers

▍Precautions for Using Refrigerant Recovery Tube Piercing Pliers

When using refrigerant recovery tube piercing pliers, it is important to take the following precautions:

1. Wear appropriate personal protective equipment, such as gloves and safety glasses, to protect yourself from refrigerant and other hazards.

2. Make sure that the AC or refrigeration system is turned off and has had time to cool down before attempting to recover the refrigerant.

3. Use the correct size piercing pin for the tube you will be piercing. Using a pin that is too large can damage the tube and cause leaks.

4. Be careful when piercing the tube to avoid damaging other components of the system.

5. Use the tube piercing pliers only for their intended purpose of recovering refrigerant. Do not use them for any other tasks.

6. Follow all safety procedures when working with refrigerant, including proper disposal of recovered refrigerant and following local regulations.

7. It is recommended to have experience or training in working with refrigerants before attempting to use the tube piercing pliers.

8. Store the refrigerant recovery tube piercing pliers in a safe location when not in use, and keep them out of reach of children and unauthorized individuals.

By following these precautions, you can safely and effectively use refrigerant recovery tube piercing pliers to recover refrigerant from an AC or refrigeration system.

Using Refrigerant Recovery Tube Piercing Pliers Safety Precautions Using Refrigerant Recovery Tube Piercing Pliers Safety Precautions

Additional information

Editor

Yjx

hzpt oem odm banner

We promise will offer the best price by the high quality in china! We also accept special order about the products. If you are interested in our products. Please do not hesitate to let us know.We are pleased to give you the detailed information.We promise that our products would be safety and were in high quality and reasonable price. If you are interested in our products, please contact us asap.We are sincerely looking for your cooperation.

Most of our products are exported to Europe or Americas, both standard and nonstandard products available. We can produce as per your drawing or sample. Material can be standard or as per your special request. If you choose us, you choose reliable.

Industries We Service

industries we service